Search results for " wearable sensors"
showing 3 items of 3 documents
Electrochemical detection of chloride ions using Ag-based electrodes obtained from compact disc
2022
Abstract In this work electrochemical sensors fabricated from compact disc material (waste or new) are used to quantify chloride ions in different types of samples. All three electrodes, working, counter, and pseudo-reference electrodes, were fabricated from the compact disc and directly used. Different parameters were studied in order to demonstrate the possibility of using this waste material for efficient and low-cost electrochemical sensors. Chloride sensing performance was evaluated using linear scan voltammetry as the detection technique. A sensitivity of 0.174 mA mM−1 cm−2 with a limit of detection of 20 μM and excellent selectivity against many interferents was observed. Selectivity…
STUDIO E VALIDAZIONE DI SISTEMI PER L’IDENTIFICAZIONE E IL MONITORAGGIO DI PARAMETRI BIOMEDICI ATTI ALLA PREVENZIONE DI EVENTI INDESIDERATI E ALL’ASS…
L’aumento delle patologie cronico-degenerative nella popolazione mondiale ha comportato un numero sempre maggiore di individui richiedenti assistenza sanitaria, generando, nell’ambito delle realtà ospedaliere, diverse problematiche relative al miglioramento della qualità di vita dei pazienti, ai costi e alla gestione di un numero sempre crescente di soggetti ammalati. Il trattamento sanitario e la ricerca di base si sono pertanto orientati verso la prevenzione delle condizioni che predispongono i soggetti ai peggioramenti clinici e ai ricoveri ospedalieri, puntando sia su nuovi sistemi indossabili di monitoraggio per individuare precocemente i segni di peggioramento, sia su sistemi che poss…
Longitudinal Gait Analysis of a Transfemoral Amputee Patient: Single-Case Report from Socket-Type to Osseointegrated Prosthesis
2023
The aim of the present case report was to provide a longitudinal functional assessment of a patient with transfemoral amputation from the preoperative status with socket-type prosthesis to one year after the osseointegration surgery. A 44 years-old male patient was scheduled for osseointegration surgery 17 years after transfemoral amputation. Gait analysis was performed through 15 wearable inertial sensors (MTw Awinda, Xsens) before surgery (patient wearing his standard socket-type prosthesis) and at 3-, 6-, and 12-month follow-ups after osseointegration. ANOVA in Statistical Parametric Mapping was used to assess the changes in amputee and sound limb hip and pelvis kinematics. The gait symm…